Gold Member Since 2017
Audited Supplier
Nanjing Kejie Analytical Instrument Co., Ltd.

Gas Chromatography, Anti-Interference Gas Chromatography, Superheat Protection Gas Chromatography manufacturer / supplier in China, offering Remarkable Performance Anti-Interference Gas Chromatography/Chromatograph, Low Temperature Biochemical Incubator, Laboratory Equipment/Laboratory Analyzer/Quaternary Low-Pressure System and so on.

(/ )

Supplier Homepage Product Chromatography Gas chromatography Remarkable Performance Anti-Interference Gas Chromatography/Chromatograph

Remarkable Performance Anti-Interference Gas Chromatography/Chromatograph

FOB Price: US $7,000-40,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $7,000-40,000/ Piece
Get Latest Price
Port: Nanjing, China
Production Capacity: 5000 Pieces/Year
Payment Terms: T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: KJ-GC522
  • Ray Type: X-Ray Spectrometer
  • Detector: FID
  • Certification: CE, ISO
  • Stationary Phase: Solid Adsorbent
  • Chromatography Type: Gas Chromatography
  • Chromatographic Column Length: 10-50m
  • Weight: 75kg
  • Package Size: 61 X 61 X 78
  • Shipping Time: 7-15days
  • Transport Package: Wooden Case
  • Origin: China
  • Appliance: Tovc
  • Gaspath System: Three
  • Energy Resolution: ≤7.5%
  • Spectrometer Detector: Si(Li)
  • Mobile Phase: Gas
  • Chromatographic Column Type: Capilary Column
  • Chromatographic Column Diameter: 0.2~0.5mm
  • Furnace Dimensions: 28 X 30 X 18cm
  • Production Time: 7-20days
  • Trademark: Kejie
  • Specification: 67 x 53 x 49 cm
Product Description
Remarkable Performance Anti-Interference Gas Chromatography/Chromatograph
Remarkable performance anti-interference gas chromatography/chromatograph


·Product Features
Advanced Microcomputer System with Excellent Control Function
The microcomputer temperature control system with remarkable performance has adopted the internationally advanced control technology, with a high precision of temperature control(within (- ∞, -0.5) and (+0.5, + ∞)), a high dependability and a better anti-interference, which is divided into 5 separate temperature control zones with the maximal control temperature up to 400ºC. Its limit temperature settings and superheat protection function guarantee the operating safety of this instrument.
Its keyboard can set parameters for various kinds of control and operation functions (including the operating parameters for the detector) with a strong logic and very simple operation.  In addition, it has functions of self diagnosis, power-off protection, 10 kinds of modes of saving and invoking files, 2 controls of external events, timing start-up/shut-down temperature control, timing procedures, parameter and range settings of detector, settings and display of polarity and current and some other functions, which enables the instrument to specifically display setting values, actual values, timings for saving and analysis of each temperature control, etc.
 
Flexible Sample Injector System Satisfying Various Analysis Requirements
The instrument can install up to three sample injectors at the same time. According to the analysis requirements, the instrument can choose the best combination of the sample injectors, each unit of such combination can control the temperature independently, and the assembly/disassembly of these sample injectors may be very simple.
 
Sample Injector with Mono Packed Column/Double Packed Columns
The device can realize the sample injection method that the sample is entered from the head of the packed column, which enables it to be widely used by various kinds of chromatographic columns and increases 6-way valves to make gas analysis. To adopt some connector pieces in the sample injector with packed column enables the instrument to finish 0.53 wide aperture capillary column analyses simply and conveniently.
 
2 Kinds of Sample Injector Systems with Capillary Columns Suitable for Various Specifications of Capillary Columns
a)     Sample injector with special-purpose capillary column, having the blowing-up function of diaphragm and the shunting regulation with back pressure valves.
b)     Shunting/non-shunting sample injector with special-purpose capillary column is furnished with independent carrier gas circuit and make-up gas, has the flowing-up function of diaphragm and the shunting regulation with back pressure valves. The cleaning solenoid value at the entry realizes the shunting/non-shunting sample handling of capillary columns through setting the timing programme.
 
Detector with High Sensitivity and Stability
The instrument can install up to three detectors, for instance FID, TCD, ECD, etc., at the same time. Upon different analysis requirements, it can adopt different combination of such detectors, so as to realize the connection of these detectors in series or in parallel conveniently.
New-type FID has lower limit of detection, which makes the disassembly and cleanout of ejector nozzle and ion collector and guarantees highly consistency of performance of each set of detectors through precisely fixing up the installation structure of the emitter.
High-sensitivity TCD adopts the rhenium-tungsten wire of high resistance and offers double amplification circuit with a sensitivity up to 5000mV·mL/mg. The unique structure of thermal protection and insulation brings TCD higher stability of performance.
Impulse-width modulation ECD constant-current source has a PC-based option of sensitivity and electrical current.
 
Double Stable Gas Circuit with High Precision
The carrier gas circuit adopts a double steady design basing on a steady pressure valve and a steady current valve. The make-up flow of air and H.2 adopts a regulation mode basing on a steady pressure valve and a needle valve. Both of the steady current valve and the needle valve adopt digital vernier knobs with high precision, repeatability and dependability. In addition, their flow control operations are quite simple and intuitionistic.
Column Heater with High Performance and Large Capacity
The column heater with large capacity can be installed conveniently and can hold capillary columns and double packed columns. It has the quick heating/cooling function through an automate back door mechanism and can realize the allowable room temperature control. The heating procedures of the column heater can be divided into 5 stages and 6 flights
Multiple Accessories Provided Free of Charge for a Carefree Installation
The instrument has a complete set of accessories for original installation, such as purifier, offers the complete enclosure installed and used for the first time, such as purifying device, exterior gas circuit pipes, wrenches, entry needle and various kinds of connectors, attached to, so user just needs to prepare the source of the gas. The above-mentioned accessories needn't be paid in addition either!
 
Powerful Data Processing System for Your Free Choices
a)     Through the built-in data acquisition board, user can utilize the workstation software to monitor the base flow, compensate for the mono packed column and process the chromatogram data on computers. 
b)     Adopting a completely independent double-way external data acquisition box and a chromatogram workstation with a combination of intelligent software, the data processing system enables the instrument to quickly acquire the chromatogram data of signal and precisely process at the same time, no matter that of the floating signal or that of the earth signal.
c)      RS232 communication board and software, connected to the workstation, realize the both-way communication and the counter-control with the mainframe, namely, finish the setting and monitoring temperature and parameters of detectors and the setting of the data processing parameter.
d)      Unique stimulation software of chromatogram stimulates to search the optimal operating conditions for chromatogram on PCs and provides with stimulation teaching of chromatogram, trainings and knowledge base of chromatogram, etc.

·Technical Parameter
Temperature Control
Range of Temperature Control: with a room temperature above 7ºC to 400 ºC (the increment is 1 ºC)
Objects of Temperature Control: column heater, detector, thermal conductivity cell, sample injector and accessories
Ascending Stages: five stages
Ascending Speed: 0.1ºC~40ºC/min (the increment is 0.1 ºC)
Constant-Temperature Period: 055minS (the increment is 1min)
Flame Ionization Detector (FID)
Sensitivity: M≤1×10-11g/s (C16)
Optimal Test Result: M≤ 8* 10-12g/s (C16)
Noise: ≤5×10-14A
Excursion: ≤6×10-13A/h
Linear Range: ≥106
Thermal Conductivity Detector (TCD)
Sensitivity: ≥2500mV·mL/mg (C16)
Noise: ≤20μV
Excursion: ≤30μV/h
Maximal Sensitivity: 10000mV·mL/mg (electronic magnification)
Linear Range: ≥104
Electron Capture Detector (ECD)
Limit of Detection: ≤2×10-13gram per second(r-666)
Linear Range: ≥103
Utmost Operating Temperature: 350ºC

·Packing&Shipping
1. Standard export wooden case with high quality cushioning material ensure the item arrive customer in good condition.
2. Carefully check every packing detail before delivery to avoid any troubles during the transportation.
3. Appointed logistics company could be used according to customers demands.
4. Do our best to make sure customer can get their goods in time

Remarkable Performance Anti-Interference Gas Chromatography/Chromatograph
 
·About Kejie Group
Nanjing Kejie Group have one researching institution and four professional production bases,which is a leading manufacturer in R&D, manufacturing and sales of gas chromatography, high efficient liquid chromatography, atomic absorption spectrometer, atomic fluorescence, UV visible spectrophotometer, headspace injector and other analytical instruments and related products. 
 Remarkable Performance Anti-Interference Gas Chromatography/Chromatograph

 
·Our Service
Our commitment to you doesn't end when your equipment is shipped-It begins.
1. One years'warranty supported by product experts
2. AMC,post warranty,24H/7D response
3. Lifetime's spare parts supply for our products
4. Long term distribution partners worldwide ensure individual on-site customer consultation and service.


·Contact Information
Address:
2nd floor, A1 building, Nanjing University of Sci&Tech,
No.129-3 Guanghua Road, Nanjing City,
Jiangsu Province, China
Postal Code: 210014

Sales Contact
Tel: 0731-84136855
Cell: +86-13824486590

FAX: 0731-89833299
 


Please feel free to submit your inquiry information to us.We will contact with you as soon as possible.

·FAQ
Q1: Are you the factory?
A1: Of course we are,we have one Researching Institution and four Professional Production Bases
 
Q2:What's the warranty period? How do you provide this?
A2:Two years (24 month).
We have very strict inspection, the instruments which you received are high-quality and reliable.
If there's any error, we'll provide you the on line solution with in 12 hours. We'll provide you the spare parts and the shipping cost totally free.
If the problem was caused by the instrument quality, and cannot be repaired, we'll ship you the new one.
 
Q3:What's the production time?
A3:Usually 20 days for production, some equipments need extra time to debug.
 
Q4:What's the Delivery method ?
A4:Light-weight cargo is usually by express , Air transport and sea shipping is acceptable (provide with safety packing)
 
Q5:What's the delivery time?
A5:According to different method and country , express will be 6~15 days
 
Q6:How to install and operate?
A6:According to each instruction manual which sent with equipment. ( We also provide after-sale technical support)
 
Q7:What's the payment term?
A7:Usually we do 50%TT deposit ,50%TT balance before shipping.Western Union, are acceptable.








 
You Might Also Like
Send your message to this supplier
Avatar
Mr. Chess
*From:
To: Mr. Chess
*Message:

Enter between 20 to 4,000 characters.