Gas Chromatograph, Laboratory Instrument, Analytical Instruments manufacturer / supplier in China, offering Gas Chromatography for Transformer Oil Analysis Equipment with Fid, Laboratory Analyzer/Gas Analyzer/Gas Chromatography/LPG Analyzer, Laboratory/Atomic Absorption Spectrometer for Chemical/Petroleum/Textile and so on.

Diamond Member Since 2017
Audited Supplier
Supplier Homepage Products Chromatography Gas chromatography Gas Chromatography for Transformer Oil Analysis Equipment with Fid

Gas Chromatography for Transformer Oil Analysis Equipment with Fid

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $5,000-10,000/ Piece
Port: Shanghai, China
Production Capacity: 5000PCS/Year
Payment Terms: T/T, Western Union
Appliance: Biochemistry
Ray Type: No Xray
Detector: FID
Certification: CE, ISO
Stationary Phase: Liquid Solvent
Mobile Phase: Gas

You Might Also Like

Loading...

Basic Info

Model NO.: GC5890N
Chromatography Type: Gas Chromatography
Chromatographic Column Type: Capilary Column
Chromatographic Column Length: 10~30cm
Chromatographic Column Diameter: 1~2mm
Weight: 70kg
Furnace Dimension: 28*30*18cm
Package Size: 61*61*78cm
Production Time: 7days
Shipping Time: 7-15days
Trademark: Kejie
Transport Package: Wooden
Specification: 67*53*49cm
Origin: China

Product Description


Gas Chromatography for Transformer Oil Analysis Equipment with Fid


GC5890N Special Gas Chromatography for Transformer Oil

.Introduction
The special GC for transformer oil is used for detecting and analyzing the dissolved gas from transformer oils. It adopts FID, TCD, nickel conversion furnace system and automatic oscillator to satisfy actual needs for users. 


.Features
4.1
 The special GC is high precise and multi-functional, while its operation interface is simple and humanized.
4.1.1The use of new integrated digital electronic circuit has stable and reliable performance, and the temperature control can be precise to 0.01ºC.
4.1.2 It has functions of boot self-diagnosis, stopwatch(convenient to detect flow), timer operation, storage protection for power off, keyboard locking, anti-interference for power mutation, network data communication and remote control. All these functions are simple to operate.


4.2 Improved uniqueness and selectivity of the injector system with various injecting ways.
4.2.1 The unique inlet design solves the injecting discrimination, while the dual-column compensation function not only solve the problem of program drift by heating, and minus the effects of background noise, so as to get the minimum LOD.
4.2.2 Equipped with humanized automatic oscillator which can save time and effort in the preparation of injections.
4.2.3 Nickel converter is matched with the detector perfectly, so that the CO and CO2 of the injection can produce CH4 and H2O with H2 under the catalysis of nickel catalyst, and then the converted injection will be detected in FID so as to reach the separating detection for the trace CO and CO2.
You can also choose auto/manual gas 6-way valve injector, headspace injector, thermal desorption injector, cracking furnace injector, methane conversion furnace injector or automatic injector and so on.


4.3 Good stability and high sensitivity of the detector and its perfect supporting facilities can satisfy your various detection requirements.
4.3.1 Using two kinds of detectors : FID and TCD
4.3.2 All these detectors can control temperature individually, while FID is easy to assemble and disassemble for cleaning and changing nozzle, and TCD has the stable time ≤20min.

 
4.4 Improved column designation for precisely controlling the programmed heating and furnace temperature, with the features of stability, balance and time-saving.
4.4.1 Increased column volume, and the intelligent backdoor system largely shortens the time for detector to keep stable and balance after the programmed heating/cooling.
4.4.2 Heating furnace temperature ramp range: environmental temperature +5ºC~420ºC.  
4.4.3 7 steps programmed heating and the heating rate is 0.1~120ºC/min.
4.4.4 You can re-calibrate the furnace temperature, and set the maximum temperature within 420ºC according to your needs for the balance time of the heating furnace temperature.


.Parameters
Column oven
Furnace dimensions 28 x 30 x 18cm
Temperature rangeRoom temperature +5~420ºC
Temperature setting1C, programmed heating rate 0.1C
Maximum heating speed120ºC/min
Temperature stabilityit will be 0.01C, when the environmental temperature changes 1C
Programmed heating7steps
Programmed heating rate0.1-120ºC/min(increment of 0.1ºC)
Column loss can be compensated (dual channel column)
FID
Maximum operating temperature400ºC
LOD≤5 x 10-12g/s[n-C16]
Drift≤5 x 10-13A/min
Noise≤2 x 10-13A
Linear dynamic range≥107
TCD
Maximum operating temperature400ºC
Sensitivity≥10000mv.mL/mg[n-C16]
Drift≤100μV/30min
Noise≤20μA
Linear dynamic range≥105

.Application fields
It is widely used in the fields of petroleum, chemical, food, pharmaceutical, environmental protection, disease control, safety supervision, water, electricity, metallurgy, scientific research and QC.

.Detail pictures


Gas Chromatography for Transformer Oil Analysis Equipment with Fid



HD LCD screen display, clear and could protect the eyes
Gas Chromatography for Transformer Oil Analysis Equipment with Fid

You can choose different detectors, for example FID/TCD/FPD/ECD/NPD
Gas Chromatography for Transformer Oil Analysis Equipment with Fid

·Packing&Shipping
(1)Standard export wooden case with high quality cushioning material ensure the item arrive customer in good condition.
(2)Carefully check every packing detail before delivery to avoid any troubles during the transportation.
(3)Appointed logistics company could be used according to customers demands.
(4)Do our best to make sure customer can get their goods in time.



Gas Chromatography for Transformer Oil Analysis Equipment with Fid



·About Kejie Group
Nanjing Kejie Group have one researching institution and four professional production bases,which is a leading manufacturer in R&D, manufacturing and sales of gas chromatography, high efficient liquid chromatography, atomic absorption spectrometer, atomic fluorescence, UV visible spectrophotometer, headspace injector and other analytical instruments and related products.


Gas Chromatography for Transformer Oil Analysis Equipment with Fid



·Our Service
Our commitment to you doesn't end when your equipment is shipped-It begins.
1,One years'warranty supported by product experts
2,AMC,post warranty,24H/7D response
3,Lifetime's spare parts supply for our products
4,Long term distribution partners worldwide ensure individual on-site customer consultation and service.

·Contact Information
Address:
2nd floor, A1 building, Nanjing University of Sci&Tech,
No.129-3 Guanghua Road, Nanjing City,
Jiangsu Province, China
Postal Code: 210014

.Sales Contact
Tel: 86-0731-84135155  
FAX: 86-0731-89833299
 

Please feel free to submit your inquiry information to us.We will contact with you as soon as possible.


·FAQ
Q1: Are you the factory?
A1: Of course we are,we have one Researching Institution and four Professional Production Bases
 
Q2:What's the warranty period? How do you provide this?
A2:Two years (24 month).
We have very strict inspection, the instruments which you received is high-quality and reliable.
If there's any error, we'll provide you the on line solution with in 12 hours. We'll provide you the spare parts and the shipping cost totally free.
If the problem was caused by the instrument quality, and cannot be repaired, we'll ship you the new one.
 
Q3:What's the production time?
A3:Usually 20 days for production, some equipment need extra time to debug.
 
Q4:What's the Dlivery method ?

A4:Light-weight cargo is usually by express , Air transport and sea shipping is acceptable (provide with safty packing)
 
Q5:What's the delivery time?
A5:According to different method and country , express will be 6~15 days
 
Q6:How to install and operate?
A6:According to each instruction manual which sent with equipment. ( We also provide after-sale technical support)
 
Q7:What's the payment term?
A7:Usually we do 50%TT deposit ,50%TT balance before shipping.Western Union, are acceptable.

 

Send your message to this supplier

*From:
*To:
avatar Mr. Chess
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now